Century S244 Spezifikationen Seite 38

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 47
  • Inhaltsverzeichnis
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 37
37
Increase air Decrease air
Air control adjustment for model FW2470
3.5 MAINTAINING THE FIRE
Once the wood has been consumed (or partially consumed) and you have obtained a good bed of
embers, you should reload the unit. In order to do so, open the air control to its maximum for
approximately 15 seconds prior to opening the stove door. Then, proceed by opening the door very
slowly. Open it by 2” to 4” (52 to 104 mm) for 10 to 15 seconds before opening it completely. This
procedure will increase the draft and thus eliminate the smoke which is stagnant in a state of slow
combustion in the stove. Then, bring the red embers to the front of the stove and reload the unit.
Depending on the type of wood you burn and the strength of the draft in your flue, you may
have to leave the air control open to its maximum for more than 15 seconds to avoid smoke
spillage before you reload the stove.
Your E.P.A Century stove will work best if a thick bed of hot embers is maintained in the bottom of
the firebox, and a minimum of two large pieces of seasoned fuel are added. Combustion efficiency is
largely related to establishing a hot ember bed, and hot firebox temperatures. The quicker the stove
and chimney (flue) get up to normal operating temperatures, the better. A small intense fire is
preferred to a large smouldering fire, both to improve combustion efficiency and to reduce the
amount of creosote build-up. The best performance will be obtained by adding relatively small
amounts of fuel to a well established ember bed, and then operating with the air inlet control open
long enough to achieve a hot fire. The wood should be placed with air in between individual pieces.
Use a poker to make an air channel in the embers below the wood. This will allow air to flow under
the wood for a more efficient burn.
In order to achieve an optimum efficiency from the S244 and the FW2470, we suggest that you
operate it with the air control completely closed. Make sure that you have a good fire going and an
adequate ember bed before you completely close the air control. Use a chimney thermometer if
necessary. Closing the air control too soon will lower combustion efficiency and may cause the fire
to die out.
Seitenansicht 37
1 2 ... 33 34 35 36 37 38 39 40 41 42 43 ... 46 47

Kommentare zu diesen Handbüchern

Keine Kommentare